Hokkien Tokong - Temple Building consist of Bored Piling, Sub- Basement RC Structure, MnE & Architecture Works


Project Info

Completion
December 2025
Scope
Desgin & Built of Façade Roof & Façade Screen
Client
Client : Selangor And Kuala Lumpur Hokkien Association

CONSTRUCTION AND COMPLETION OF MAIN BUILDING WORKS FOR CADANGAN MEMBINA SEBUAH TOKONG 3 TINGKAT DENGAN 1 TINGKAT DI BAWAH PARAS JALAN BERSERTA TEMBOK PENAHAN DI ATAS LOT 20000 YANG AKAN DIHUBUNGKAN KEPADA TOKONG SEDIA ADA DI ATAS LOT 194, JALAN MAHARAJALELA, WILAYAH PERSEKUTUAN KUALA LUMPUR UNTUK TETUAN SELANGOR AND KUALA LUMPUR HOKKIEN ASSOCIATION

Needs: Client want to do façade screen using huge hollow section & façade roof using steel section with 7m cantilever

Problem: The façade screen section up to size 400mm x 600mm was too huge to use hollow section and 7m cantilever façade roof

Solution: we propose to make up the façade screen section using steel plate with internal frame and solving the 7m cantilever roof using DBS steel truss design